StatTank
- Last UpdatedDec 13, 2022
- 2 minute read
The following table lists the available object properties in the StatTank object type.
|
Property |
Description |
Type |
|
Name |
Name of the tank |
String |
|
Description |
Description |
String |
|
StartDateTime |
Service start date |
String |
|
MassVolume |
Default mass inventory or calculation equation of inventory |
Numeric or String |
|
VolVolume |
Default volume inventory or calculation equation of inventory |
Numeric or String |
|
MinMassCap |
Minimum mass inventory capacity |
Numeric |
|
MinVolCap |
Minimum volume inventory capacity |
Numeric |
|
MaxMassCap |
Maximum mass inventory capacity |
Numeric |
|
MaxVolCap |
Maximum volume inventory capacity |
Numeric |
|
HeelMassVolume |
Heel Mass Inventory |
Numeric |
|
HeelVolVolume |
Heel Volume Inventory |
Numeric |
|
ProdGroup |
Product Group |
String |
|
MixFactor |
Mixing factor in composition tracking simulation |
Numeric |
|
Properties |
Property name and its tag or default value with a semicolon separator |
String |
|
Components |
Component name and its tag or default value with a semicolon separator |
String |
|
TagName |
Tag name for inventory measurement |
String |
|
ImpUnit |
Import engineering unit for inventory measurement |
String |
|
BalanceType |
Balance Type (MASS, VOLUME, BOTH) |
String |
|
ComponentUnit |
Import component engineering unit (wt%, vol%.) |
String |
|
MorU |
Measured(M) or Unmeasured (U) |
String |
|
FlowType |
Type of Tank. All tanks are of type I (Inventory). |
String |
|
ProdCode |
Product code (or name) |
String |
|
Phase |
Phase status (L (Liquid), G (Gas), S (Solid)) |
String |
|
MassAbsolute |
Absolute tolerance value of mass inventory |
Numeric |
|
VolAbsolute |
Absolute tolerance value of volume inventory |
Numeric |
|
MassRelative |
Relative tolerance value of mass inventory |
Numeric |
|
VolRelative |
Relative tolerance value of volume inventory |
Numeric |
|
Density |
Default density |
Numeric |
|
MW |
Default molecular weight |
Numeric |
|
Temperature |
Default temperature |
Numeric |
|
Pressure |
Default pressure |
Numeric |
|
bCompensation |
Whether to use compensation or not |
Boolean |
|
bComponent |
Whether to use component data to calculate density and MW or not |
Boolean |
|
DensityTag |
Density tag name |
String |
|
MWTag |
MW tag name |
String |
|
TemperatureTag |
Temperature tag name |
String |
|
PressureTag |
Pressure tag name |
String |
|
AnalyzerTag |
Analyzer name |
String |
|
KValue |
K value for inventory compensation |
Numeric |
|
Model |
Model name which the tank belongs to |
String |
|
bTracking |
Whether or not the tank is included in composition tracking |
Boolean |
|
bUseRec |
Whether to use the reconciled value of the previous period’s inventory as the starting inventory |
Boolean |
|
bLive |
Whether the tank is live or not |
Boolean |
|
bEventDetection |
Whether automatic event detection from the tank’s inventory change information is applied or not |
Boolean |
|
bTankDiffOS |
Whether to set inventory difference stream to out of service when the tank is active or not |
Boolean |
|
bGS |
Whether to select "User Define as Gross Error" or not |
Boolean |
|
bNGS |
Whether to select "User Define as Not Gross Error" or not |
Boolean |
|
bLogical |
Whether the tank is of type "logical" or not |
Boolean |
|
bOS |
whether or not the tank is out of service |
Boolean |