Sections - Offset to Joints

  • Last UpdatedAug 14, 2025
  • 1 minute read

Checks the GENSEC where the distance of the JLDATU references and the position of the GENSEC vary more than the distance input.

The offset can be caused by manual adjustment of the joint, causing incorrect beam positions when output.

To realign the joint, disconnect and reconnect the end of the beam. Refer to Connect Sections and Disconnect Sections for further information.