Specify only certain elements for output. Below are examples of variations of this command

Output Syntax for Sites Only

OUTPUT ONLY SITE /HTEST

Output

INPUT BEGIN

NEW SITE /HTEST

POS E 0 N 0 U 1000

END

INPUT END /HTEST

INPUT FINISH

Output Syntax for Branches Only

OUTPUT ONLY BRAN /HTEST

Output

INPUT BEGIN

NEW BRANCH /100-B-1-B1

BUIL false

SHOP false

HPOS E 12490 N 12280 U 1150

TPOS E 4979 N 9887 U 13655

HDIR U

TDIR N

UCOFG E 0 N 0 U 0

LHEA true

LTAI true

HBOR 50

TBOR 100

HCON FBD

TCON FBD

DETA true

LNTP unset

TEMP -100000

PRES 0

HSTU /A3B/PA50

CCEN 0

CCLA 0

PSPE /A3B

DUTY unset

DSCO unset

PTSP unset

INSC unset

PTNB 0

DELDSG unset

END

Output Syntax for Nozzles and Branches

OUTPUT ONLY (NOZZ BRAN) /HTEST

Output

NEW NOZZLE /VENT_OUT

UCOFG E 0 N 0 U 0

POS E 0 S 500 U 1600

ORI Y is U and Z is S

TEMP -100000

PRES 0

HEIG 200

DUTY unset

DESP 400 200 25 5

END

NEW BRANCH /100-B-1-B1

BUIL false

SHOP false

HPOS E 12490 N 12280 U 1150

TPOS E 4979 N 9887 U 13655

HDIR U

TDIR N

UCOFG E 0 N 0 U 0

LHEA true

LTAI true

HBOR 50

TBOR 100

HCON FBD

TCON FBD

DETA true

LNTP unset

TEMP -100000

PRES 0

HSTU /A3B/PA50

CCEN 0

CCLA 0

PSPE /A3B

DUTY unset

DSCO unset

PTSP unset

INSC unset

PTNB 0

DELDSG unset

END