The task of creating an HVAC Component is initiated from the HVAC Window.
-
Select Flat Oval in the Categories drop-down list and then ‘B’ Plane 4 Segment Bend in the Available Type drop-down list to display the 4 Segment B Bend window:

-
You are required to input the following dimensions:
-
Duct Width AA
-
Duct Depth AB
-
Angle
-
Inside Radius
-
Arrive Extension
-
Leave Extension
-
-
To visualize how the dimensions equate to the actual piece of HVAC, click Picture to display a detailed drawing for ‘B’ Plane 4 Segment Bend (CAFO).
Note: The fields will be pre-populated with default dimensions These dimensions are governed by the details defined in the HVAC Catalogue. The Arrive and Leave Extension is auto but can be changed by you to a required dimension.
-
Click Transpose Width/Depth to exchange Duct Width AA dimension with Duct Depth AB dimension.
-
Specify a type of joint to use for the Arrive Joint and Leave Joint. Refer to Create/Modify HVAC Component for a detailed description.
-
After selecting the type of joint for the Arrive Joint and Leave Joint you must enter the Leave Direction.
-
In Leave Direction specify the Axis that should be used. Valid axes are E (East), N (North), U (Up), -E (negative East), -N (negative North) or -U (Negative Up).X, Y, Z, -X, -Y or -Z.
-
In the Position list, select Connect or Unchanged:
-
Click Connect (default when Create is selected) - connects the piece of HVAC to the previous one.
-
Click Unchanged (default when Modify is selected) - positions the component at the co-ordinates 0.00.
Note: Unchanged is usually used, when Modify is selected, it does not connect the component but positions it at 0.00, in effect in a floating position.
-
-
Click Defaults to reset all the fields back to when the 4 Segment B Bend window was opened.
-
Click Fit to orientate the 4 Segment B Bend component to automatically match the outlet (p-leave) of the previous piece of HVAC to the inlet (p-arrive) of the next piece.
-
Click OK to create the 4 Segment B Bend component and close the 4 Segment B Bend Window. You will be returned to the HVAC Window.
-
Click Cancel to discard all field changes and close the 4 Segment B Bend window.