Limits Tab
- Last UpdatedMar 12, 2026
- 1 minute read
Creating an Obstruction/Exclusion list is not the only way you can set the obstructions. Using the Limits tab you can create an area around items or a region to create an obstruction box. Any element that lies partly or wholly within the limits box is checked. A clash between items that lie partially within the limits box is always reported, even if the point at which the clash occurs lies outside the box.
-
Right-click within the From or To panes but outside of the text fields to display a pop-up menu which allows you to change how the From and To limits are displayed.
-
Format ENU
-
-
You can set the limits of the obstruction box, enter the values in the text fields or select an option from the Volume drop-down list.
-
To disable (lock) the limits of the obstruction box, select the required East, North, Up check box.
-
Click Clear to set the values defining the corners of the obstruction box to zero.
Note: A setting of zero in all the fields is by default to include all the elements and primitives in the current MDB.
-
To display the Volume box in the 3D graphical view, select Display check box.