Structural Components Selectors
- Last UpdatedMay 10, 2023
- 2 minute read
The following SELEC questions are those which you are likely to use when defining SPECs for structural components:
SType
Defines the Specific Type of the component; particularly applicable to the general generic types PROF, JOIN and FITT. Examples of STYPE answers which might be applied to structural components to cover European, American and British standards include:
STYPE Meaning
C Channel section or American standard C–shapes (tapered flanges)
CHS Circular hollow section
CRSJ Castellated rolled steel joists
CUB Castellated universal beams
CUC Castellated universal columns
CZB Castellated Z–beams
EAI Imperial equal angles
EAM Metric equal angles
HD European columns (wide flanges)
HE European beams (wide flanges)
HL/HX European beams (very wide flanges)
HP Bearing piles (wide flanges)
IPE European beams (parallel faced flanges)
IPN European standard beams (tapered flanges)
LST Long stalk tee–bars
M/W American I–shapes (wide flanges)
RHS Rectangular hollow section
RSJ Rolled steel joists
S American standard I–shapes (tapered flanges)
T Tee bars
TUB Tees cut from universal beams
TUC Tees cut from universal columns
U European small channels
UB Universal beams
UBP Universal bearing piles
UC Universal columns
UEAI Imperial unequal angles
UEAM Metric unequal angles
UPN European standard channels
PLAT Plate girders
DEPth
The depth (height) of a structural section; e.g. 100 mm.
WIDth
The width of a structural section; e.g. 100 mm.
WEIGht
The weight per unit length; e.g. 100 kg/m.
DIMEnsion integer
Any dimension. The qualifying integer is optional; suggested conventions are:
DIME1
Depth or long leg
DIME2
Width or short leg
CTYPE integer
A connection type. The qualifying integer is optional; suggested conventions are:
CTYPE1
Start connection
CTYPE2
End connection
CTYPE3
Attached connection
CTYPE4
Owning connection
with the possible answers RIVET, BOLT, WELD, GLUE, etc.
CTYStart
Start connection (equivalent to CTYPE1).
CTYEnd
End connection (equivalent to CTYPE2).
CTYAttached
Attached connection (equivalent to CTYPE3).
CTYOwning
Owning connection (equivalent to CTYPE4).
INERtia integer
Moment of inertia about a specified axis; e.g. 280 cm$. (It is usually convenient to use cm rather than mm here to avoid having to list large values.) The qualifying integer is optional; suggested conventions are:
INER1
Inertia about x-x
INER2
Inertia about y-y
INER3
Inertia about u-u
INER4
Inertia about v-v
THICkness integer
Plate thickness within a section; e.g. 10 mm. The qualifying integer is optional; suggested conventions are:
THIC1
Web thickness
THIC2
Flange thickness
FIXty
Joint fixity; e.g. FIXED, PINNED, PLASTIC, HINGED, RIGID, etc.
GRADe
Material grade for fire-resistant insulation; e.g. 43. (See Structural Insulation.)
FIREsistance
Degree of fire resistance for insulation; e.g. 2 hr. (See Structural Insulation.)
ITHIckness
Insulation thickness; e.g. 50 mm. (See Structural Insulation.)
AREA
Area of a section; e.g. 100 cm².
As for piping component specifications, you may also use any word, with or without a numeric qualifier, to define your own questions. See Piping Component Selectors.