Representation Tab
- Last UpdatedMar 05, 2026
- 4 minute read
The Representation tab of the Graphics Settings window allows you to set some of the general and piping representation parameters and presents control options allowing you to display further windows for specifying the representations of more specific parameters.

The general and piping Representation parameters are:
|
Tube |
Select Tube check box to display double line representation of piping components. |
|
Centreline |
Select Centreline check box to display single line representation of piping components. |
|
Holes Drawn |
Select Holes Drawn check box to display holes (negative primitives) as true holes, rather than as black lines in a shaded view. |
|
Flange Bolt Holes Drawn |
Select Flange Bolt Holes Drawn check box to display bolt holes drawn on flanges. |
|
Tracing |
Select Tracing check box to display tracing. |
|
Anti-Alias |
Select Anti-Alias check box to display anti-alias lines. The Anti-Alias level determines how fine a diagonal line is drawn; the higher the number the finer the line. However, the higher the level the more computer workstation CPU is required. |
|
|
|
|
Insulation Visibility/ |
If selected, Insulation Visibility/Translucency is displayed on the piping components and tubing, as defined in the catalogue. Click on the drop-down menu to specify a level of translucency between 0% (Off) and 100% (Solid). |
|
Obstruction Visibility/ Translucency |
If selected, Obstruction Visibility/Translucency volumes are displayed, as defined in the catalogue (but only if the drawing level is set appropriately). Click on the drop-down menu to specify a level of translucency between 0% (Off) and 100% (Solid). |
|
Level |
Separate drawing levels can be set for each of the following categories. In each case, enter the required level (which must be in the range 1-99) into the corresponding text box: |
|
|
|
To make sure the correct TCTL (True CuT Length) value on SCTN elements with negative geometry taken into account, you must set the Mass representation level to 6 before querying the True Cut Length, assuming level 6 is used to represent detail geometry in the structural steel catalogue. |
|
|
Arc Tolerance |
Defines the tolerance within which arcs must be drawn. To change the tolerance, edit the number in the text box. |
Click Representation Rules to display the Representation Rules window. You can Create, Edit, Save and Load various representation rules, to be applied to various element types.

Rules can be set from the Representation Settings pane:
|
Gtype |
Select the Gtype element (Generic type) from the drop-down menu. |
|
Rule Expression |
Enter a Rule Expression in the text box (for example bore gt 80mm), if required. |
|
Tube |
Select Tube check box to display double line representation of piping components. |
|
Centreline |
Select Centreline check box to display single line representation of piping components. |
|
Insulation |
If selected, Insulation is displayed on the piping components and tubing, as defined in the catalogue. Click on the drop-down menu to specify a level of translucency between 0% (Off) and 100% (Solid). |
|
Obstruction |
If selected, Obstruction volumes are displayed, as defined in the catalogue (but only if the drawing level is set appropriately). Click on the drop-down menu to specify a level of translucency between 0% (Off) and 100% (Solid). |
|
Level |
Enter the drawing Level for the relevant Gtype element. In each case, enter the required level (which must be in the range 1-99). |
|
Arc Tolerance |
Defines the tolerance within which arcs must be drawn. To change the tolerance, edit the number in the text box. |
|
Add to End of List |
Click Add to End of List to add the new representation rule to the Representation List. |
|
Replace Selection |
Click Replace Selection to replace an existing representation rule. |
-
Once you have added or replaced a representation rule, click Apply to apply the rules to the graphical display.
-
To restore the display to the default settings, click Reset Display.
-
To save Representation Rules set, select File > Save or to load a created rule set select File > Load.
-
Once you have completed configuring the Representation settings, click Apply to apply the settings. Click Dismiss to discard any changes made.
-
Click Load or Save, to load from and save to the options files stored at %AVEVA_DESIGN_USER%.