Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

Everything E3D

Ignoring Clashes at Steelwork Junctions

  • Last UpdatedJan 11, 2024
  • 1 minute read

Keywords:

INCLUDE IGNORE CONNECTIONS ALL WITH SPECIFICATIONS

Description:

This facility allows the user to control checking at steelwork junctions. (Clashes between sections and attached joints are ignored automatically.)

Frequently, the user may wish to leave end preparations at steelwork joints until late in the design process. This option can inhibit clash reporting using the commands described here.

Examples:

INCLUDE CONNECTIONS

Includes all steelwork connections during subsequent clash checking.

IGNORE CONNECTIONS

Ignores steelwork connections during checking.

IGNORE CONNECTIONS WITH SPECIFICATIONS

Ignores only those connections which have specifications.

Command Syntax:

>-- INClude -- CONnections -->


>-- IGNore --+-- ALL --.
             |         |
             ‘---------+-- CONnections -->


>-- IGNore -- CONnections -- WIth -- SPEcifications -->

Related Links