The task of creating an HVAC Component is initiated from the HVAC Window.
-
Select Rectangular in the Categories drop-down list and then ‘A’ Plane Splitter in the Available Type drop-down list to display the ‘A’Plane Splitter window:

-
You are required to input the following dimensions:
-
Duct Width AA
-
Duct Depth AB
-
Duct Width LA
-
Duct Depth LB
-
Length
-
A Offset
-
B Offset
-
Arrive Extension
-
Leave Extension
-
Splitter F Offset
-
Splitter L Offset
-
-
To visualize how the dimensions equate to the actual piece of HVAC click Picture to display a detailed drawing for ‘A’ Plane Splitter (CAR).
Note: The fields will be pre-populated with default dimensions. These dimensions are governed by the details defined in the HVAC Catalogue.
-
Click Transpose Width/Depth to exchange Duct Width AA dimension with Duct Width AB dimension or to exchange Duct Width LA dimension with Duct Width LB dimension.
-
Specify a type of joint to use for the Arrive Joint and Leave Joint. Refer to Create/Modify HVAC Component for a detailed description.
-
After selecting the type of joint for the Arrive Joint and Leave Joint you must enter the A Offset Direction.
-
In A Offset Direction enter the direction for the A Offset relative to the Point of Origin. Valid directions are E (East), N (North), U (Up), -E (negative East), -N (negative North) or -U (Negative Up).X, Y, Z, -X, -Y or -Z.
-
In the Position list, select Connect or Unchanged:
-
Click Connect (default when Create is selected) - connects the piece of HVAC to the previous one.
-
Click Unchanged (default when Modify is selected) - positions the component at the co-ordinates 0.00.
Note: Unchanged is usually used, when Modify is selected, it does not connect the component but positions it at 0.00, in effect in a floating position.
-
-
Click Defaults to reset all the fields back to when the ‘A’ Plane Splitter window was opened.
-
Click Fit to orientate the ‘A’ Plane Splitter to automatically match the outlet (p-leave) of the previous piece of HVAC to the inlet (p-arrive) of the next piece.
-
Click OK to create the ‘A’ Plane Splitter component and close the ‘A’ Plane Splitter Window. You will be returned to the HVAC Window.
-
Click Cancel to discard all field changes and close the ‘A’ Plane Splitter window.