Locate and Replace
- Last UpdatedJan 05, 2023
- 2 minute read
The following Locate and Replace syntax is possible
Output syntax locate/replace
OUTPUT LOCATE REPLACE /E1301
Output
INPUT BEGIN
NEW LOCATE SITE /HTEST
NEW LOCATE ZONE /EQUIP
NEW REPLACE EQUIPMENT /E1301
POS E 2850 N 5660 U 1470
UCOFG E 0 N 0 U 0
BUIL true
DSCO unset
PTSP unset
INSC unset
NEW CYLINDER
POS E 0 N 3299 U 0
ORI Y is D and Z is N
LEVE 0 4
DIAM 960
HEIG 6598
END
NEW CYLINDER
POS E 0 N 6848 U 0
ORI Y is D and Z is N
LEVE 0 4
DIAM 1020
HEIG 500
END
Output Syntax Replace Only
OUTPUT REPLACE /E1301
Output
INPUT BEGIN
NEW REPLACE EQUIPMENT /E1301
POS E 2850 N 5660 U 1470
UCOFG E 0 N 0 U 0
BUIL true
DSCO unset
PTSP unset
INSC unset
NEW CYLINDER
POS E 0 N 3299 U 0
ORI Y is D and Z is N
LEVE 0 4
DIAM 960
HEIG 6598
END
NEW CYLINDER
POS E 0 N 6848 U 0
ORI Y is D and Z is N
LEVE 0 4
DIAM 1020
HEIG 500
END
NEW BOX
POS E 0 N 1710 D 315
LEVE 0 8
XLEN 460
YLEN 300
ZLEN 630
END
Output syntax Locate only
OUTPUT LOCATE /E1301
Output
INPUT BEGIN
NEW LOCATE SITE /HTEST
NEW LOCATE ZONE /EQUIP
NEW EQUIPMENT /E1301
POS E 2850 N 5660 U 1470
UCOFG E 0 N 0 U 0
BUIL true
DSCO unset
PTSP unset
INSC unset
NEW CYLINDER
POS E 0 N 3299 U 0
ORI Y is D and Z is N
LEVE 0 4
DIAM 960
HEIG 6598
END
NEW CYLINDER
POS E 0 N 6848 U 0
ORI Y is D and Z is N
LEVE 0 4
DIAM 1020
HEIG 500
END
NEW BOX
POS E 0 N 1710 D 315
LEVE 0 8
XLEN 460
YLEN 300
ZLEN 630
END