Flat Low Vel’ Terminal (CEIE)
- Last UpdatedMay 22, 2026
- 3 minute read
The task of creating an HVAC Component is initiated from the HVAC Window.
-
Select Extra Inline Equipment in the Categories drop-down list and then Flat Low Vel’ Terminal in the Available Type drop-down list to display the Flat LV Terminal window:

-
The Flat LV Terminal window default is a standard stock size, but can be changed by you using the following two methods:
-
Standard Stock Sizes:
-
In the Name(Ref) field, input the name of the HVAC component.
Note: The fields will be pre-populated with default dimensions. These dimensions are governed by the details defined in the HVAC Catalogue.
-
To choose from the standard stock sizes available from the HVAC Catalogue, in the Stock Size drop-down list, click the size for the HVAC component.
-
In the Handling drop-down list, click the Handling of the Flat LV Terminal.
-
In the Direction X specify the axis that should be used. Valid axes are E (East), N (North), U (Up), -E (negative East), -N (negative North) or -U (Negative Up).X, Y, Z, -X, -Y or -Z.
The Face Clash Volume field is pre-populated with the obstruction volume associated with the Flat LV Terminal and the ducting.
-
-
Non Standard Stock Sizes (Special)
-
If you chose not to use a standard stock piece of HVAC, from the Stock Size drop-down list, click Special.
-
-
-
You are required to input the following dimensions:
-
Name(Ref)
-
Duct Diameter
-
End Width (A)
-
End Height (D)
-
End Depth
-
Plenum Width (B)
-
Plenum Height (E)
-
Plenum Depth (G)
-
-
Top Width (C)
-
Top Height
-
Top Depth (F)
-
Top to Conn cl(l)
-
Centreline Offset
-
Arrive Extension
-
-
To visualize how the dimensions equate to the actual piece of HVAC, click Picture to display a detailed drawing for Flat Low Velocity Terminal (CAEPE).
Note: The fields will be pre-populated with default dimensions. These dimensions are governed by the details defined in the HVAC Catalogue.
-
Specify a type of joint to use for the Arrive Joint and Leave Joint. Refer to Create/Modify HVAC Component for a detailed description.
-
After selecting the type of joint to use for the Arrive Joint and Leave Joint you must enter the Direction X.
-
In the Direction X specify the axis that should be used. Valid axes are E (East), N (North), U (Up), -E (negative East), -N (negative North) or -U (Negative Up).X, Y, Z, -X, -Y or -Z.
-
The Face Clash Volume field is pre-populated with the obstruction volume associated with the Flat LV Terminal and the ducting.
-
In the Position list, select Connect or Unchanged:
-
Click Connect (default when Create is selected) - connects the piece of HVAC to the previous one.
-
Click Unchanged (default when Modify is selected) - positions the component at the co-ordinates 0.00.
Note: Unchanged is usually used, when Modify is selected, it does not connect the component but positions it at 0.00, in effect in a floating position.
-
-
You can orientate the face of the Flat LV Terminal component, from the Handling drop-down list, select Face Back or Face Front.
-
Click Defaults to reset all the fields back to when the Flat LV Terminal window was opened.
-
Click Fit to orientate the Flat LV Terminal to automatically match the outlet (p-leave) of the previous piece of HVAC to the inlet (p-arrive) of the next piece.
-
Click OK to create the Flat LV Terminal component and close the Flat LV Terminal Window. You will be returned to the HVAC Window.
-
Click Cancel to discard all the field changes and close the Flat LV Terminal window.