Rectangular Motorised Damper r (CIPE)
- Last UpdatedMay 22, 2026
- 2 minute read
The task of creating an HVAC Component is initiated from the HVAC Window.
-
Select Inline Plant Equipment in the Categories drop-down list and then RECTANGULAR, Motorized Damper in the Available Type drop-down list to display the Motorized Damper window:

-
You are required to input the following dimensions:
-
MVCD Name(Ref)
-
Duct Width AA
-
Duct Depth AB
-
Length
-
Spindle Direction
-
-
To visualize how the dimensions equate to the actual piece of HVAC, click Picture to display a detailed drawing for Rectangular Motorised Damper (CAIPE).
Note: The fields will be pre-populated with default dimensions. These dimensions are governed by the details defined in the HVAC Catalogue.
-
Click Transpose Width/Depth to exchange Duct Width AA dimension with the Duct Width AB dimension.
-
Specify a type of joint to use for the Arrive Joint and Leave Joint. Refer to Create/Modify HVAC Component for a detailed description.
-
After selecting the type of joint to use for the Arrive Joint and Leave Joint you must enter the Spindle Direction.
-
In the Spindle Direction specify the axis that should be used. Valid axes are E (East), N (North), U (Up), -E (negative East), -N (negative North) or -U (Negative Up).X, Y, Z, -X, -Y or -Z.
-
The Clash Vol fields will be pre-populated with the obstruction volumes associated with the rectangular flanged FD component and the ducting, but can be changed by you.
-
In the Position list, select Connect or Unchanged:
-
Click Connect (default when Create is selected) - connects the piece of HVAC to the previous one.
-
Click Unchanged (default when Modify is selected) - positions the component at the co-ordinates 0.00.
Note: Unchanged is usually used, when Modify is selected, it does not connect the component but positions it at 0.00, in effect in a floating position.
-
-
Click Defaults to reset all the fields back to when the Motorised Damper window was opened.
-
Click Fit to orientate the Motorised Damper to automatically match the outlet (p-leave) of the previous piece of HVAC to the inlet (p-arrive) of the next piece.
-
Click OK to create the Motorised Damper component and close the Motorised Damper Window. You will be returned to the HVAC Window.
-
Click Cancel to discard all the field changes and close the Motorised Damper window.