Circular Mitred c (CBC)
- Last UpdatedMay 21, 2026
- 2 minute read
The task of creating an HVAC Component is initiated from the HVAC Window.
-
Select Branch Connectors in the Categories drop-down list and then CIRCULAR, Mitred c in the Available Type drop-down list to display the Mitred Brconnector window:

-
You are required to input the following dimensions:
-
Branch Connector Diameter
-
MAIN Width LA
-
MAIN Depth LB
-
Branch Connector Length
-
Distance from Leave
-
B offset
-
Branch Connector Extension
-
Fixing to Duct
-
Male Collar
-
Inner Extension
-
-
To visualize how the dimensions equate to the actual piece of HVAC, click Picture to display a detailed drawing for Circular Mitred (CABC).
Note: The fields will be pre-populated with default dimensions. These dimensions are governed by the details defined in the HVAC Catalogue. The Branch Connector Extension default is auto but can be changed by you to a required dimension. The Fixing to Duct joint default is joint defined in the HVAC Catalogue but can be changed by you to the required joint.
-
Click Transpose Width/Depth to exchange MAIN Width LA dimension with MAIN Depth LB dimension.
-
Specify a type of joint to use for the Branch Connector Joint. Refer to for a detailed description.
-
After selecting the type of joint to use for the Branch Connector Joint, you must enter the Branch Connector Direction.
-
In Branch Connector Direction specify axis that should be used. Valid axes are E (East), N (North), U (Up), -E (negative East), -N (negative North) or -U (Negative Up).X, Y, Z, -X, -Y or -Z.
-
In the Position list, select Connect or Unchanged:
-
Click Connect (default when Create is selected) - connects the piece of HVAC to the previous one.
-
Click Unchanged (default when Modify is selected) - positions the piece of HVAC at the co-ordinates 0.00.
Note: Unchanged is usually used, when Modify is selected, it does not connect the piece of HVAC but positions it at 0.00, in effect in a floating position.
-
-
Click Defaults to reset all the fields back to when the miterd Brconnector window was opened.
-
Click Fit To Next to orientate the miterd Branch Connector to automatically fit this piece of HVAC to the next piece.
-
Click OK to create the miterd Branch Connector component and close the miterd Brconnector Window. You will be returned to the HVAC Window.
-
Click Cancel to discard all field changes and close the miterd Brconnector window.