Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

AVEVA™ Everything E3D

Combined Pipework Tolerance and Tube Length Options

Combined Pipework Tolerance and Tube Length Options

  • Last UpdatedJan 11, 2024
  • 1 minute read

Keywords:

TOLERANCE OPTIONS DEFAULT

Description:

The OPTIONS command allows the user to reset defaults for, or query, all data consistency checking options for Tubes at the same time.

Example:

TOL OPTIONS DEFAULT

Resets the following data-checking parameters:

  • Offset tolerance to 1 mm

  • Angle tolerance to 0.0573 degrees

  • Ratio tolerance to 0.001

  • Maxangle setting to 90 degrees

  • Minimum tube length for all bores to 100 mm

  • ATTACHECK option to ON

Command Syntax:

>-- TOLerance OPTions DEFault -->

Querying:

>-- Query TOLerance OPTions -->

Outputs the current settings for all data checking parameters. The parameters are output in the current units.

Querying Examples:

With all default settings in force, the output resulting from a Q TOL OPT command will show one of the following sets of values (depending upon the current units):

MM Bores and Distances:

Minimum tube length : 100 mm
Tolerance Offset    : 1 mm
Tolerance Angle     : 0.0573
Tolerance Ratio     : 0.001
Maximum Angle       : 90
Atta checking       : ON

INCH Bores and Distances:

Minimum tube length : 3.9 in
Tolerance Offset    : 0 in
Tolerance Angle     : 0.0573
Tolerance Ratio     : 0.001
Maximum Angle       : 90
Atta checking       : ON

FINCH Bores and Distances:

Minimum tube length : 3.15/16
Tolerance Offset    : 0.1/32
Tolerance Angle     : 0.0573
Tolerance Ratio     : 0.001
Maximum Angle       : 90
Atta checking       : ON