Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

AVEVA™ Production Accounting

Formulas

  • Last UpdatedFeb 28, 2025
  • 1 minute read

Formulas are built in the Equation Editor dialog. In addition to smart object functions as described above, AVEVA Production Accounting supports many built-in functions. They can be grouped as:

  • Mathematical functions

  • Text functions

  • Date & Time functions

  • Statistical functions

  • Logical functions

Details for each function are described in the Function section of the Equation Editor dialog when you select the function.

Below are some realistic examples of the kinds of built-in and smart object functions that our customers use.

Examples of default flow rate equation for stream object type

If(Month(Model(StartDateTime)) >= 10 Or Month(Model(StartDateTime)) <= 3, Stream(LS_WWT;MassFlowrate)*0.8,0)

(Stream(EG2FQI139;MassFlowrate)/28.054*(1-(120-35*(Stream(EG2FQI163;MassFlowrate)/Stream(EG2FQI139;MassFlowrate)))/100)*2*44.01)*1

(Node(ENERGY_BRU;MassFlowrate)-Node(ENERGY_BRU;MassRunrate))/Stream(ENERGY_SP_BRU_BZ;MassFlowrate)*1000

If(Abs(Stream(LOSS_SS_C4R1;RecMassFlowrate))>StatStream(LOSS_SS_C4R1;MinMassRate)*2,Stream(V_BD2FI104;MassFlowrate),Stream(V_BD2FI104;MassFlowrate)-Stream(LOSS_SS_C4R1;MassFlowrate))

If((Stream(BZ2FC6010;MassFlowrate)-Tank(B5436-F;MassDelta)-Stream(VC1FI946;MassFlowrate)-Stream(V_OS2FQI234_S;MassFlowrate)-Stream(NC2FQI1064;MassFlowrate)+Tank(B10-124-F;MassDelta))>10,Stream(BZ2FC6010;MassFlowrate)-Tank(B5436-F;MassDelta)-Stream(VC1FI946;MassFlowrate)-Stream(V_OS2FQI234_S;MassFlowrate)-Stream(NC2FQI1064;MassFlowrate)+Tank(B10-124-F;MassDelta),0)

If(Stream(B1_FI873;MassFlowrate)<10,12-Stream(B1_FI873;MassFlowrate),0)

If((Stream(V_IP20_TSS;MassFlowrate)+Tank(U-FB128B;MassDelta))>5,(Stream(V_IP20_TSS;MassFlowrate)+Tank(U-FB128B;MassDelta))*0.8,0)

(STREAM(V_T3-PIC1302A_N2;MASSFLOWRATE)*STREAM(V_T3-PIC1302A;COMPONENT;CO)+STREAM(V_T3-PIC1302B_N2;MASSFLOWRATE)*STREAM(V_T3-PIC1302B;COMPONENT;CO)+STREAM(V_T3-PIC1401_N2;MASSFLOWRATE)*STREAM(V_T3-PIC1401;COMPONENT;CO))/100

Examples of default inventory equation of tank object type

Tank(B5432-FC;MassVolume)+Tank(B5432-FD;MassVolume)+Tank(B5435-F;MassVolume)+Tank(B5439-F;MassVolume)-Tank(V_B5432-F_LG; MassVolume)

TANK(T3-D1605_IBA;MASSVOLUME)*TANK(T3-D1605_IBA;COMPONENT;PX)/100