Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

AVEVA™ Process Simulation

Correlation 27

  • Last UpdatedMar 07, 2023
  • 1 minute read

The following table lists the identification numbers of this correlation with respect to some well-known sources of thermodynamic data.

Source

Correlation Number

SimSci

27

PPDS

5

DIPPR 801

-

NIST TDE

23

DECHEMA IK-CAPE PPDX

-

The equation has the following form:

TempDep Corr 27

Equation for T-sub(r) where T-sub(r) equals T divided by T-sub(C)

You must use 3 coefficients with this correlation.

You can use any temperature unit of measure (UOM) when you input data for this correlation. However, AVEVA Thermodynamic Data Manager converts temperatures to Kelvin (K) before it calculates the property value.

Usage

We recommend that you use this correlation to calculate only the following property:

  • Vapor Viscosity