Mode summary for the F3 example simulation
- Last UpdatedSep 19, 2024
- 1 minute read
|
Mode |
Process |
Fluid Flow |
|---|---|---|
|
Objective |
Size the relief valves based on required flow. Size the inlet and tail pipe diameters based on rated flow. |
Calculate the relief valve back pressures. |
|
Sources |
Specify the required flow. |
Specify the required flow. |
|
Relief Valves |
Size the relief valve by selecting a relief valve orifice letter designation. |
Calculate the back pressure based on the downstream piping. Calculate the required fraction of relief valve capacity. |
|
Pipes |
Calculate the required nominal pipe size. Calculate the downstream pressure. |
Set the inside diameter based on the nominal pipe size. Calculate the upstream pressure from the flow. Check for choked flow. |
|
Mixers |
Set the outlet pressure to the minimum inlet pressures. |
Set all inlet and outlet pressures to be the same pressure. |
|
Converter |
Convert the Compositional fluid to a FlareGas fluid based on the temperature, molecular weight, and Cp/Cv ratio. |
Convert the Compositional fluid to a FlareGas fluid based on the temperature, molecular weight, and Cp/Cv ratio. |
|
Stack |
Calculate the pressure from upstream piping. |
Set the pressure to atmospheric pressure. |