The following table compares the existing actual pipe sizes with the calculated diameter required for a 3 m/s flow rate. Only 10 pipes are shown for brevity. See the Excel document for a complete report. We size all pipes such that no pipes are grossly oversized and the velocity is lower than the minimum velocity.

Pipe

Size

Required Flow (kg/hr)

Velocity (m/s)

Calculated Diameter

Action

NPS (in)

DN (mm)

(in)

(mm)

P001

16

DN400

794852

3

12

306

No Change

P1

14

DN300

794852

3

12

306

No Change

P10

6

DN150

151413

3

5

134

No Change

P11

4

DN100

80430

3

4

97

No Change

P12

4

DN100

46715

3

3

74

No Change

P13

6

DN150

104698

3

4

111

No Change

P14

4

DN100

64562

3

3

87

No Change

P15

4

DN100

40135

3

3

69

No Change

P15A

6

DN150

127145

3

5

122

No Change

P15B

6

DN150

104698

3

4.

111

No Change