Process mode results for the U4 example simulation
- Last UpdatedOct 04, 2024
- 1 minute read
The following table compares the existing actual pipe sizes with the calculated diameter required for a 3 m/s flow rate. Only 10 pipes are shown for brevity. See the Excel document for a complete report. We size all pipes such that no pipes are grossly oversized and the velocity is lower than the minimum velocity.
|
Pipe |
Size |
Required Flow (kg/hr) |
Velocity (m/s) |
Calculated Diameter |
Action |
||
|---|---|---|---|---|---|---|---|
|
NPS (in) |
DN (mm) |
(in) |
(mm) |
||||
|
P001 |
16 |
DN400 |
794852 |
3 |
12 |
306 |
No Change |
|
P1 |
14 |
DN300 |
794852 |
3 |
12 |
306 |
No Change |
|
P10 |
6 |
DN150 |
151413 |
3 |
5 |
134 |
No Change |
|
P11 |
4 |
DN100 |
80430 |
3 |
4 |
97 |
No Change |
|
P12 |
4 |
DN100 |
46715 |
3 |
3 |
74 |
No Change |
|
P13 |
6 |
DN150 |
104698 |
3 |
4 |
111 |
No Change |
|
P14 |
4 |
DN100 |
64562 |
3 |
3 |
87 |
No Change |
|
P15 |
4 |
DN100 |
40135 |
3 |
3 |
69 |
No Change |
|
P15A |
6 |
DN150 |
127145 |
3 |
5 |
122 |
No Change |
|
P15B |
6 |
DN150 |
104698 |
3 |
4. |
111 |
No Change |