Fluid Flow mode for the F1 example simulation
- Last UpdatedOct 04, 2024
- 1 minute read
The purpose of Fluid Flow mode is to determine PSV back pressures at relieving conditions. In Fluid Flow mode, all of the mixers provide a pressure balance and pipes use their nominal pipe inside diameter. We make the following assumptions:
-
As in Process mode, we specify the flow at each source.
-
We calculate the relief valve back pressure based on the flare stack pressure at atmospheric pressure.
-
We model several relief events as different combinations of relieving relief valves, which we save as the following snapshots to show the resulting imposed back pressure on the different relief valves.
-
FF1 - All valves are open.
-
FF2 - Total power failure occurs.
-
FF3 - Cooling water failure occurs.
-