Process mode results for the U6 example simulation
- Last UpdatedOct 04, 2024
- 1 minute read
The following table compares the pipe sizes with the calculated diameter required for a velocity of 3 m/s.
|
Pipe |
NPS (in) |
Flowrate (kg/hr) |
Velocity (m/s) |
Calculated Diameter (in) |
|---|---|---|---|---|
|
PIPE1 |
4in |
50000 |
3.0 |
3 |
|
PIPE2 |
4in |
25000 |
3.0 |
2 |
|
PIPE3 |
4in |
25000 |
3.0 |
4 |
|
PIPE4 |
4in |
50000 |
3.0 |
3 |
|
PIPE5 |
4in |
50000 |
3.0 |
3 |
|
PIPE6 |
3in |
25000 |
3.0 |
2 |
|
PIPE9 |
3in |
25000 |
3.0 |
2 |
|
PIPE10 |
4in |
50000 |
3.0 |
3 |
|
PIPE11 |
3in |
45000 |
3.0 |
3 |
|
PIPE12 |
2in |
5000 |
3.0 |
2 |