The following table compares the pipe sizes with the calculated diameter required for a velocity of 3 m/s.

Pipe

NPS (in)

Flowrate (kg/hr)

Velocity (m/s)

Calculated Diameter (in)

PIPE1

4in

50000

3.0

3

PIPE2

4in

25000

3.0

2

PIPE3

4in

25000

3.0

4

PIPE4

4in

50000

3.0

3

PIPE5

4in

50000

3.0

3

PIPE6

3in

25000

3.0

2

PIPE9

3in

25000

3.0

2

PIPE10

4in

50000

3.0

3

PIPE11

3in

45000

3.0

3

PIPE12

2in

5000

3.0

2