The following table compares the actual flow to the required flow for each heat exchanger and provides the outlet temperature based on the required duty in the table in Process description for the U4 example simulation.

Exchanger

Required Duty (kW)

Required Flow (kg/hr)

Actual Flow (kg/hr)

Cooling Water Outlet Temperature (°C)

E11

927.5

80430

78392

45.5

E12

538.5

46715

46211

45.4

E14

744.2

64562

62144

45.6

E15

462.6

40135

39651

45.4

E20

1779.9

63170

65341

44.2

E20A

1116.7

39636

42040

43.6

E22

1780.7

63198

67799

43.3

E22A

1117

39645

42000

43.6

E27

3567.6

126618

194156

36.5

E28

1930.7

68525

106573

36.3

E30

2944.4

104503

155226

37.0

E31

1626.1

57715

83911

37.4

E4

649.2

39182

29075

39.9

E4A

649.2

39179

29073

39.9

E6

910.3

54933

59439

33.9

E7A

1633.1

98548

108812

33.6

The following table provides the pump requirements and pump performance with one of two pumps operating.

Pump

Pump A (m3/hr)

Pump B (m3/h)

Total Flow (m3/h)

DP (kPa)

Required Flow (Process Mode)

397.4

397.4

794.9

1241

Two Pumps Operating

491.7

491.7

983.4

897.4

One Pump Operating

536.6

0

536.6

642