Simulation model
- Last UpdatedSep 19, 2024
- 1 minute read
The two adsorption beds are identical. We model the adsorption beds according to the following specifications:
-
We use one (NLayers = 1) BedLayer submodel with 40 segments (Layer[1].Ne = 40) of alternating bed and wall elements.
-
We calculate the pressure drop according to Ergun3 (PressureDrop = Ergun).
-
We create copies of the RatesLocal, RatesLDF, IsothermInert, and IsothermExLangmuir submodels from the Adsorption library in the simulation-specific library. Then, we update the rate expressions, saturation concentration calculations, and equilibrium loading calculations to match the empirical data that we have for our alumina adsorbent.
-
We use the RatesLDF submodel from the simulation-specific library to calculate the adsorption rates of N2 and O2. These linear driving force (LDF) rate expressions are based on the paper by Farooq and Ruthven1.
-
We use the IsothermExLangmuir submodel from the simulation-specific library to calculate the saturation concentrations and equilibrium loading. We calculate the equilibrium loading by using the Extended Langmuir equation.
-
We model the outlet valve by using a first-order time constant (Tc) of 0.02 seconds.