AVEVA™ Process Simulation

Mode summary for the U4 example simulation

  • Last UpdatedSep 20, 2024
  • 1 minute read

The following table provides a summary of the simulation operation in all three modes:

Process

Fluid Flow

Dynamic

Purpose

Size pipes for required flow rates. Check heat exchanger outlet temperatures.

Determine the actual flow rate distribution though the network.

Not applicable.

Pumps

Estimate pressure rise.

Operate on a performance curve

Pipes

Calculate diameter to check nominal pipe size requirements.

Set the Inside diameter based on nominal pipe size.

Mixers

Use the minimum of inlet pressures.

Set all inlet and outlet pressures the same.

Heat Exchangers

Specify required flow for flow balance. Check outlet temperature.

Calculate actual flow based on reference conditions.