Dynamics mode results for the GG1 example simulation

Dynamics mode results for the GG1 example simulation

  • Last UpdatedOct 04, 2024
  • 2 minute read

Scenario 1: Motor trip with a cold recycle anti-surge valve

Run the Motor Trip with Cold Recycle Scenario and observe the following results:

Scenario 2: Blocked outlet with a cold recycle anti-surge valve

Run the Blocked Outlet with Cold Recycle Scenario observe the following results:

Scenario 3: Motor trip with a hot recycle anti-surge valve

Run the Motor Trip with Hot Recycle Scenario and observe the following results:

Scenario 4: Blocked outlet with a hot recycle anti-surge valve

Run the Blocked Outlet with Hot Recycle Scenario and observe the following results:

Comparison of maximum outlet temperatures

The following figures show the comparison of the maximum compressor outlet temperature for the blocked outlet scenarios for the hot and cold recycle anti-surge valves:

The maximum temperature for the blocked outlet Scenario for the cold recycle anti-surge valve is 122.6°C (395.7 K).

The maximum temperature for the blocked outlet Scenario for the hot recycle anti-surge valve is 123.4°C (396.6 K).