Configure an equation-based Fluid Type
- Last UpdatedJan 31, 2025
- 2 minute read
These Fluid Types use one of the following Thermo Types:
-
FlareGas
-
IdealGas
-
IncompressibleLiquid
They use internal equations to calculate their thermodynamic properties and do not need any external code or software to perform calculations.
Configure an equation-based Fluid Type
-
Open the Fluid Editor for the Fluid Type.
Expand the Starting Values section and enter the Initial value, Minimum value, and Maximum value for the Pressure and Temperature.

-
Expand the Parameters section and enter the values for your fluid.
The default value for FlareGas fluids is a CpCv value of 1.4.

The default values for IdealGas fluids are the properties for air.

The default values for IncompressibleLiquid fluids are the properties for water.