AVEVA™ Process Simulation

Dynamics mode for the AA3 example simulation

  • Last UpdatedOct 04, 2024
  • 1 minute read

We use Dynamics mode to study the compositional profile during the adsorption cycles.

Each pressure swing adsorption (PSA) cycle involves the following four steps:

  1. Pressurization: Pressurize Bed 1 and vent Bed 2.

  2. Production: Produce high-purity oxygen from Bed 1 and continue to vent Bed 2.

  3. Blowdown: Pressurize Bed 2 and vent Bed 1.

  4. Purge: Produce high-purity oxygen from Bed 2 and continue to vent Bed 1.

We provide respective scenarios for each step. The following images illustrate the valve settings specific to each step, where green indicates a fully opened valve, red indicates a fully closed valve, and yellow indicates a 50% opening position for the valve.

Figure 3: Valve setup for each PSA step

We also provide a scenario that runs a full cycle (that is, all four steps), a scenario that runs five cycles, and a scenario that runs ten cycles. See the following section for more information.

Related Links