We use Dynamics mode to study the compositional profile during the adsorption cycles.
Each pressure swing adsorption (PSA) cycle involves the following four steps:
-
Pressurization: Pressurize Bed 1 and vent Bed 2.
-
Production: Produce high-purity oxygen from Bed 1 and continue to vent Bed 2.
-
Blowdown: Pressurize Bed 2 and vent Bed 1.
-
Purge: Produce high-purity oxygen from Bed 2 and continue to vent Bed 1.
We provide respective scenarios for each step. The following images illustrate the valve settings specific to each step, where green indicates a fully opened valve, red indicates a fully closed valve, and yellow indicates a 50% opening position for the valve.

Figure 3: Valve setup for each PSA step