Fluid Flow mode results for the U6 example simulation

Fluid Flow mode results for the U6 example simulation

  • Last UpdatedOct 04, 2024
  • 1 minute read

The following table compares the actual flow to the required flow for each heat exchanger and provides the outlet temperature based on the required duty specified in Process description for the U6 example simulation.

Exchanger

Duty (kW)

Required Flow (kg/hr)

Actual Flow (kg/hr)

Required Outlet Temperature (°C)

E1

1280

16000

18207

80

E2

1280

26176

29334

80

FHTR

2698

20141

21427

400

The following table provides the pump requirements and pump performance with one of two pumps operating. You can find the results for when Pump 2 trips in the Snapshot FF 2.

Pump

Pump 1 (kg/hr)

Pump 2 (kg/h)

Total Flow (kg/h)

DP (kPa)

Required Flow (Process Mode)

25000

25000

50000

370

Two Pumps Operating

25000

25000

50000

370

One Pump Operating

35883

0

35883

130