The purpose of Fluid Flow mode is to determine PSV back pressures at relieving conditions. In Fluid Flow mode, all of the mixers provide a pressure balance and pipes use their nominal pipe inside diameter. We make the following assumptions:

  • As in Process mode, we specify the flow at each source.

  • We calculate the relief valve back pressure based on the flare stack pressure at atmospheric pressure, and pressure drop through the piping system.

  • We model several relief events as different combinations of relieving relief valves, which we save as the following snapshots to show the resulting imposed back pressure on the different relief valves.

    • FF 1 - All valves are open.

    • FF 2 – Total power failure occurs.

    • FF 3 – Cooling water failure occurs.