Mode summary for the F1 example simulation
- Last UpdatedSep 19, 2024
- 1 minute read
|
Mode |
Process |
Fluid Flow |
|---|---|---|
|
Objective |
Size relief valves based on required flow. Size pipe diameters. |
Calculate relief valve back pressures. |
|
Sources |
Specify required flow. |
Specify required flow. |
|
Relief Valves |
Size relief valve by selecting a relief valve orifice letter designation. |
Report the back pressure that AVEVA Process Simulation calculates by using the downstream piping. Calculate the required fraction of relief valve capacity. |
|
Pipes |
Calculate approximate diameter. Calculate downstream pressure. |
Set inside diameter based on nominal pipe size. Calculate upstream pressure from flow. Check for choked flow. |
|
Mixers |
Set pressure to the minimum inlet pressures. |
Set all outlet pressures to be the same as the inlet pressures. |
|
Stack |
Calculate pressure from upstream piping. |
Set pressure to atmospheric pressure. |