Reference state
- Last UpdatedAug 13, 2024
- 1 minute read
For multi-component methods developed by AVEVA, the reference states are as follows:
-
Enthalpy: Ideal Gas Heat of Formation at 25°C and 1 bar
-
Entropy: Ideal Gas at 1 K and 1 bar
IF97 — IAPWS Industrial Formulation 1997 uses its own reference state as described in its documentation.