Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

AVEVA™ Process Simulation

Fluid Flow mode results for the F3 example simulation

Fluid Flow mode results for the F3 example simulation

  • Last UpdatedOct 04, 2024
  • 2 minute read

The following table shows the relief valve back pressures after all the equipment has been properly rated in Fluid Flow mode. The Type is Conventional for all the relief valves.

Variable

Name

UOM

RV1

RV2

RV3

RV4

RV5

RV6

Size

Size

L

L

J

J

K

L

Area

A

mm2

1840.00

1840.00

830.00

830.00

1185.00

1840.00

Capacity

Capacity

%

0.67

0.70

0.63

0.91

0.87

0.66

Rated mass flow

W

kg/h

11339.81

22679.62

34019.43

4535.92

9071.85

13607.77

Set pressure

SP

kPa

1005.79

1205.36

2768.87

614.62

1255.85

1688.08

Inlet pressure

P1

kPa

1207.69

1427.22

3147.08

777.40

1482.76

1958.21

Back pressure

Pb

kPa

134.68

131.41

118.19

122.75

125.18

118.40

Back pressure fraction

BPf

%

3.32

2.50

0.61

3.49

1.90

1.01

The following table shows the relief valve inlet pipes properly sized for rated capacity. The Flow Model is Incompressible and the Design Basis is RatedCapacity for all the inlet pipes.

Variable

UOM

PI1

PI2

PI3

PI4

PI5

PI6

Size

4in

4in

3in

3in

3in

4in

Mass Flow

kg/h

16091.59

28606.14

38044.81

4481.85

10292.56

21060.19

Diameter

mm

102.26

102.26

77.93

77.93

77.93

102.26

Diameter Margin

mm

37.56

42.35

43.10

34.11

18.95

27.87

Length

m

9.14

9.14

9.14

9.14

9.14

9.14

Moody Friction

0.02

0.02

0.02

0.02

0.02

0.02

Inlet Pressure

kPa

1172.37

1302.09

2689.10

711.19

1505.77

2015.89

Outlet Pressure

kPa

1156.62

1278.35

2679.92

702.77

1471.35

1988.59

Inlet Velocity

m/s

39.46

33.60

4.07

31.29

55.99

52.20

Outlet Velocity

m/s

40.03

34.32

19.98

31.67

57.30

52.92

Pressure Drop

kPa

15.75

23.74

9.18

8.42

34.42

27.30

DP Percent

%

1.64

2.22

0.39

1.54

2.76

1.59

The following table shows the relief valve tail pipes properly sized for rated capacity. The Flow Model is Isothermal and the Design Basis is RatedCapacity for all the tail pipes.

Variable

UOM

PT1

PT2

PT3

PT4

PT5

PT6

Size

8in

10in

12in

6in

8in

12in

Mass Flow

kg/h

16091.59

28606.14

38044.81

4481.85

10292.56

21060.19

Diameter

mm

202.72

254.51

303.23

154.05

202.72

303.23

Diameter Margin

mm

7.51

55.82

151.76

51.13

19.66

11.53

Length

m

15.24

15.24

15.24

15.24

15.24

15.24

Moody Friction

0.00

0.00

0.00

0.00

0.00

0.00

Inlet Pressure

kPa

122.50

118.31

110.85

146.66

149.01

139.81

Outlet Pressure

kPa

113.45

113.45

108.16

144.57

144.57

137.25

Inlet Velocity

m/s

101.54

67.45

51.01

39.44

83.83

85.72

Outlet Velocity

m/s

109.69

70.36

52.29

40.02

86.41

87.32

Inlet Mach

Ma1

0.34

0.30

0.26

0.13

0.22

0.22

Outlet Mach

Ma2

0.37

0.31

0.27

0.14

0.23

0.23

Pressure Drop

kPa

9.05

4.86

2.69

2.10

4.45

2.56

DP Percent

%

7.39

4.11

2.43

1.43

2.98

1.83

Related Links
TitleResults for “How to create a CRG?”Also Available in