Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

AVEVA™ Process Simulation

Process mode results for the C1 example simulation

  • Last UpdatedOct 04, 2024
  • 1 minute read

The following table summarizes the stream properties for both the conceptual design simulation as well as the extended simulation by displaying properties of the input and output streams for the Column.

Table 7: Stream summary

Variable Description

UOM

MeOH_Water

Reflux

Reboiler Return

DIST

BOTTOMS

HotSteam

CW

Mass Flow (W)

kg/h

31,653

14,877

59,617

13,747

17,906

15,096

308,928

Mole Flow (F)

kmol/h

1,430

473

3,309

437

993

837

17,148

Pressure (P)

kPa

150

101

127

100

115

475

150

Temperature (T)

°C

78

65

106

64.8

103

150

25

Vapor Fraction (VF)

fraction

0.00

0.00

0.30

0.00

0.00

1.00

0.00

Methanol Composition (z[METHANOL])

fraction

0.29

0.96

0.002

0.96

0.00

Water Composition (z[WATER])

fraction

0.71

0.04

0.998

0.04

1.00

The columns for the Reflux, Reboiler Return, HotSteam, and CW streams apply only to the extended simulation model. The conceptual design simulation calculates the reflux and reboiler return internally and does not use utility streams.

The VLT Profile plot shows the column vapor flow, liquid flow, and temperature across the column stages.

Figure 3: Column profile plot

Related Links