Process description for the GG1 example simulation
- Last UpdatedSep 19, 2024
- 1 minute read
The compressor system consists of the following:
-
A Source model that contains the fluid that must be pressurized to send to the downstream unit.
-
An inlet valve XV1, which acts as a check valve to avoid back flow to the upstream unit.
-
A knockout drum V1, which ensures that compressor inlet is completely vapor.
-
An after cooler E1, which cools the compressed gas to the required temperature at the downstream unit.
-
A cold recycle anti-surge valve FV1 that is downstream of E1.
-
A hot recycle anti-surge valve FV2 that is upstream of E1.