Mode summary for the F4 example simulation
- Last UpdatedSep 19, 2024
- 1 minute read
|
Mode |
Process |
Fluid Flow |
|---|---|---|
|
Objective |
Size the relief valves based on required flow. Size the pipe diameters. |
Calculate the relief valve back pressures. |
|
Sources |
Specify the required flow. |
Specify the required flow. |
|
Relief Valves |
Size the relief valve by selecting a letter designation for the relief valve orifice. |
Report the back pressure that AVEVA Process Simulation calculates by using the downstream piping. Calculate the required fraction of relief valve capacity. |
|
Pipes |
Calculate the approximate diameter. Calculate the downstream pressure. |
Set the inside diameter based on nominal pipe size. Calculate the upstream pressure from the flow. |
|
Mixers |
Set the pressure to the minimum inlet pressures. |
Set all outlet pressures to be the same as their respective inlet pressures. |
|
Drum |
Specify a liquid level fraction. Calculate the vapor and liquid outlet flow. |
Calculate the liquid level fraction based on the accumulated holdup volume. Calculate the pressure from the differential mass and energy balances. |
|
Valves |
Specify the DP to size Cv. |
Set the Cv to calculate the flow. |
|
Stack |
Calculate the pressure from the upstream piping. |
Set the pressure to atmospheric pressure. |