Mode summary for the U6 example simulation

  • Last UpdatedSep 20, 2024
  • 1 minute read

The following table provides a summary of the simulation operation in all three modes:

Process

Fluid Flow

Dynamics

Purpose

Size the pipes for required flow rates. Check the heat exchanger outlet temperatures.

Determine the actual flow distribution through the network.

Perform dynamic studies.

Pumps

Estimate the pressure rise.

Operate based on performance curve.

Operate based on performance curve.

Pipes

Calculate the diameter to check nominal pipe size requirements.

Set the inside diameter based on nominal pipe size.

Set the inside diameter based on nominal pipe size.

Mixers

Use the minimum of inlet pressures.

Set all inlet and outlet pressures the same.

Set all inlet and outlet pressures the same.

Splitters

Set the split fraction to the required flow rate.

Calculate the split fraction based on the flow from the system hydraulics.

Calculate the split fraction based on the flow from the system hydraulics.

Heat Exchangers

Specify the required flow for the required heat transfer. Check the outlet temperature.

Calculate the actual flow based on reference conditions.

Calculate the actual flow based on reference conditions.

Flow Controller

Calculate the set point and process variable based on specified conditions.

Calculate the process variable based on specified conditions.

Adjust the controller output position with time.

Temperature Controller

Calculate the set point based on specified conditions.

Calculate the process variable based on the desired set point.

Adjust the valve position with time.