Mode summary for the U6 example simulation
- Last UpdatedSep 20, 2024
- 1 minute read
The following table provides a summary of the simulation operation in all three modes:
|
Process |
Fluid Flow |
Dynamics |
|
|---|---|---|---|
|
Purpose |
Size the pipes for required flow rates. Check the heat exchanger outlet temperatures. |
Determine the actual flow distribution through the network. |
Perform dynamic studies. |
|
Pumps |
Estimate the pressure rise. |
Operate based on performance curve. |
Operate based on performance curve. |
|
Pipes |
Calculate the diameter to check nominal pipe size requirements. |
Set the inside diameter based on nominal pipe size. |
Set the inside diameter based on nominal pipe size. |
|
Mixers |
Use the minimum of inlet pressures. |
Set all inlet and outlet pressures the same. |
Set all inlet and outlet pressures the same. |
|
Splitters |
Set the split fraction to the required flow rate. |
Calculate the split fraction based on the flow from the system hydraulics. |
Calculate the split fraction based on the flow from the system hydraulics. |
|
Heat Exchangers |
Specify the required flow for the required heat transfer. Check the outlet temperature. |
Calculate the actual flow based on reference conditions. |
Calculate the actual flow based on reference conditions. |
|
Flow Controller |
Calculate the set point and process variable based on specified conditions. |
Calculate the process variable based on specified conditions. |
Adjust the controller output position with time. |
|
Temperature Controller |
Calculate the set point based on specified conditions. |
Calculate the process variable based on the desired set point. |
Adjust the valve position with time. |