Process mode for the GG1 example simulation
- Last UpdatedSep 19, 2024
- 1 minute read
The purpose of Process mode is to design the compressor at steady-state operation. Some important aspects include:
-
Size the control valves for the required steady-state pressure drops with 50% open position.
-
Set the anti-surge valve for zero flow during normal steady-state operations by using the following setup:
-
Set the header outlet ratio (OutRatio) for the anti-surge recycle streams to zero.
-
Set the anti-surge Cv to an initial value that you should validate in Dynamics mode.
-
Calculate the output variable (OP) for the anti-surge controller. Because you set the OutRatio for the anti-surge recycle streams to zero, the anti-surge flow is zero and AVEVA Process Simulation initially calculates OP as zero.
-
-
Set the exchanger outlet temperature as required.