Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

AVEVA™ Process Simulation

Mode summary for the U2 example simulation

  • Last UpdatedSep 19, 2024
  • 1 minute read

The following table provides a summary of the simulation operation in all three modes:

Process

Fluid Flow

Dynamic

Purpose

Calculate turbine power production at a given flow and inlet pressure.

Size the control valves.

Calculate turbine power production at alternate conditions, such as partially closed feed valves and different source and sink pressures.

View dynamic responses after the setpoint for the header pressure changes.

Tune pressure controls for faster response.

Source

Specify flow.

Specify pressure.

Calculate flow.

Specify pressure.

Same as Fluid Flow.

Valves

Specify the manual position.

Calculate the Cv.

Specify the manual position.

Specify the Cv.

Same as Fluid Flow.

Header

Specify the operating pressure.

Calculate the header volume.

Calculate the pressure from the pressure balance.

Same as Fluid Flow.

Turbine

Specify the efficiency.

Specify the efficiency and expander flow area.

Calculate the flow.

Same as Fluid Flow.

Pressure Controller

Specify the pressure controller output to set the turbine governor position.

Specify the setpoint.

Calculate the controller output, which sets the turbine governor position.

Change the setpoint to simulate the dynamic response of the simulation.

Related Links
TitleResults for “How to create a CRG?”Also Available in