AVEVA™ Process Simulation

Mode summary for the U1 example simulation

  • Last UpdatedSep 19, 2024
  • 1 minute read

The following table provides a summary of the simulation operation in all three modes:

Process

Fluid Flow

Dynamic

Purpose

Size pipes for required flow rates. Check exchanger outlet temperatures.

Determine the actual flow rate distribution though the network.

Not used.

Pump

Operates at estimated pressure rise.

Operates on its performance curve.

Pipes

Calculate diameters to check nominal pipe size requirements.

Set inside diameters based on nominal pipe size.

Mixer

Set pressure to the minimum of inlet pressures.

Operate at a pressure balanced state. All inlet and outlet pressures are the same.

Heat Exchangers

Specify the required flow. Check the outlet temperature.

Calculate actual flow based on reference conditions.

Related Links