<StartReprocessingRequestMessage xmlns="http://www.citect.com/Ampla/Inventory/2010/03">

<Request>

<Credentials>

<Password>********</Password>

<Session />

<Username>User</Username>

</Credentials>

<ReprocessFromDateTime>2018-07-01T00:00:00</ReprocessFromDateTime>

</Request>

</StartReprocessingRequestMessage>

Request parameters: Credentials section

The Credentials section contains the security details for authentication. You can provide the Username and Password values to use the Basic security method. If you do not provide explicit security values, Web services will attempt to use Integrated authentication. You must provide either Basic credentials, Integrated credentials, or a Session ID.

<Credentials>

<Username>User</Username>

<Password>********</Password>

<Session />

</Credentials>

Parameter

Description

Username

The login name of the AVEVA™ Production Management user. This is a string value. Username and Password together are mutually exclusive with Session.

Password

The password that is associated with the AVEVA Production Management user. This is a string value. Username and Password together are mutually exclusive with Session.

Session

A GUID string value that identifies the session. This is a string value. Mutually exclusive with Username and Password.

Request parameters: Request section

<Request>

<ReprocessFromDateTime>2018-07-01T00:00:00</ReprocessFromDateTime>

<PendingChanges>1</PendingChanges>

</Request>

or

<Request>

<ReprocessFromDateTime xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:nil="true" />

<PendingChanges>0</PendingChanges>

</Request>

Parameter

Description

ReprocessFromDateTime

The time and date that AVEVA™ Production Management should begin reprocessing events from. This time must be in UTC ISO 8601 format.

  • When PendingChanges is set to 1, then ReprocessFrom DateTime does not need to be set.

  • When PendingChanges is set to 0 and no date is specified, AVEVA™ Production Management will attempt to reprocess all records from all time.

PendingChanges

This parameter automatically determines the appropriate data window to reprocess pending changes. When PendingChanges is set to 1, then ReprocessFromDateTime does not need to be set.