Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

AVEVA™ Production Management

Configure Behavior properties

  • Last UpdatedFeb 25, 2025
  • 5 minute read

These properties appear in the Behavior category of a Downtime field.

Note: Depending on your selections, some properties may appear or disappear from the available set of properties.

Studio Properties pane showing the properties for downtime field in Behavior section.

Behavior properties

Property

Description

Valid values

Action

Defines whether this field stores a value with each record or whether it retrieves a value from the Calendar when the record is accessed by AVEVA™ Production Management.

For more information, see Lookup Calendar.

  • If this property is LookupCalendar, specify the ItemName in the Calendar

CalendarItem - Enter the ItemName in the Calendar table. AVEVA™ Production Management retrieves the item value based on the ItemName and ActiveDateTime pair. The CalenderItem property is available only when the Action property is set to LookupCalendar.

Example

ItemName [ActiveDateTime, Item Value]

ItemName [ActiveDateTime, Item Value]

Directs AVEVA™ Production Management to lookup the value of ItemValue associated with specified ItemName in the dbo.Calendar table, based on ActiveDateTime.

Valid values: ItemName in the dbo. Calendar table of project data SQL database.

  • If the Action property is Store, specify the calculation and capture values.

Store, LookupCalendar

CalculationType

Specifies the calculation type of this field. The available options will be different depending on type of reporting point.

For more information, see Configure the Calculation Type property for fields.

None, Accumulator, Inventory, Integral, Average, Time Weighted Average, Minimum, Maximum

CaptureDataWhen

Specifies the Downtime state that triggers a data capture.

By default the value is set to EventStateOn which would cause odd capture behavior for an Accumulator calculator. The correct setting for an Accumulator would be EventStateOff or EventStateOffAndAutoSplit.

For more information, see Configure the Capture Data When property.

EventStateOn,

EventStateOff, EventStateOnandOff, EventStateOnAndAutoSplit, EventStateOffAndAutoSplit, EventStateOnOffAndAutoSplit, EventStateConfirmation

CaptureValueForManualRecords

Specifies whether the field uses the expression result as the default value in manual records.

True, False

DataType

The data type for the field. This is an important value for storing and aggregating data correctly. The correct data type is critical to the ability of Production Analyst to display and aggregate information in fields.

The type you select can cause different options to display in the Properties pane. If it is a numeric data type, you can optionally specify the Minimum and Maximum values under the Details Display category.

The data type is required information, however, sometimes can be supplied by the SourceField.

For more information, see Configure the Data Type property for fields.

If the data type is String, set the String-related properties that determine text entry properties. See StringType property.

Boolean, Date, Double, Integer, Long, Single, String.

DisplayFormat

This value specifies the formatting of numeric data types: Date Double, Integer, Long, and Single.

For each different numeric data type there is a default format; for example, 0.######. For more information, see Configure the Display Format property for fields.

0.######

FieldType

Specifies the type of field as an ID field or Other. When this value is ID, the FieldIDType property appears.

A field that has the DataType property set to String and the FieldType property set to ID is available for Grouping by in charts and reports. For more information, see Configure the Field Type property for fields.

ID, Other.

FieldIDType

This property appears when FieldType is set to ID. Specifies the type of ID field used in grouping data in the charts.

For more information, see Configure the Field ID Type property for fields.

ProductID, LotID, EquipmentID, Other.

Filterable

Specifies whether the field is filterable in the Production Analyst data results.

True, False.

HasBudget

Indicates whether the field has a budget associated with it. If the field should have a budget value, select True. A budget sub-item appears beneath the field.

Studio project hierarchy view showing the budget item in a field definition.

True, False.

HasTarget

Indicates whether the field has a target associated with it. If the field should have a target value, select True. A target sub-item appears beneath the field.

Studio project hierarchy view showing the target item in a field definition.

True, False.

HasTrendDirection

Indicates whether the field has a trend direction associated with it. If the field should have an additional trend direction field, select True.

A trend direction sub-item appears beneath the field to specify properties of the trend direction field.

Embedded Image (65% Scaling) (LIVE)

An additional Trend Direction field appears next to the custom field in the Results grid. An arrow indicates the trend over time based on the last 5 rows. The method of calculation is simple linear regression.

Embedded Image (65% Scaling) (LIVE)

True, False.

HistorialFieldExpression

Specifies the value or source of value to be stored.

Click Browse (...) to open the Expression Editor. Use the Expression Editor to build an historical expression that defines the raw field value.

Any valid expression.

RefreshOnManualEntry

Specifies whether the expression is recalculated for manual entry. Set the CaptureValueForManualRecords property to True for this property to be effective.

Select True to get new values for manual records, but not for automatic records.

True, False.

RefreshValueOnCapture

Specifies whether the value of an expression is refreshed when the field is captured, rather than only when the expression subscription triggers are activated.

In many cases, this value is set to True to enable accurate capture of the last recent value. The application refreshes the sample stream upon field capture and make a new value available for automatic and manual records.

True, False.

StringType

This property appears when DataType is set to String. It specifies the formatting type of the string data.

You can set the string type as:

  • PlainText - This option enables the user to enter plain text only.

  • HyperLink - This option enables user to enter a linked Internet address.

For String Type, set the MaximumEditLength and VisibleRows properties under the Details Display category.

PlainText, HyperLink.

Units

Any string value to use as the units in the display. Used for display purposes in AVEVA™ Production Management.

Any string value

In This Topic