Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

AVEVA™ Production Management

Example: Capturing energy use during Downtime events

Example: Capturing energy use during Downtime events

  • Last UpdatedMar 05, 2025
  • 1 minute read

This topic provides an example to capture energy waste with the Downtime module. In this example, the goal is to add and configure the kWh field, so that you can track energy usage during Downtime events.

Example: Capturing Energy use during Downtime events

One way that you can identify energy waste is to track the amount of energy being used during a Downtime event. A lot of energy use may occur even though production is interrupted, and no product is coming through.

Configure an additional field for Downtime reporting point

  • Add a custom field to a Downtime reporting point and rename the field to kWh.

Studio project hierarchy view showing the added custom field named kWh in a downtime reporting point.

  • Set the following properties for the field:

    Property

    Value

    CaptureDataWhen

    EventStateOffAndAutoSplit

    DataType

    Double

    CalculationType

    Integral

    RefreshValueOnCapture

    True

    Units

    kWh

    Sum

    SummaryType

  • Define the HistoricalFieldExpression property for the kWh field.

    Project.[System Configuration].DataSources.OpcHda.HPRC.Inst_kW.Samples[time]/3600.0

    Note: An integral calculation type expects the time units to be in seconds. Assuming that Inst_kW (in the example given) is in the units kW (per hour), you divide the sample by 3600 to convert the Inst_kW figure from a per hour value into a per second value. For example, kW / 3600.0.