Change Pool Size of Farm Connection Settings
- Last UpdatedJun 06, 2024
- 1 minute read
To change Pool Size of the Farm
-
On the Windows Start menu, point to Programs, point to AVEVA, and then click Farm Configuration Wizard.
The AVEVA Work Tasks Farm Configuration Wizard appears.
-
Click Next.
-
Select Database Settings.
-
Click Next.
The Connect to existing database screen appears.
-
Select the Connection String option.
-
Enter the pool size in the Advanced Settings field.
For example, type Connection Timeout = 30.
-
Click Test Connection.
-
Click OK.
This will change the pool size of the Farm Database.
-
Click Next.
The message, appears.
-
Stop the following AVEVA Work Tasks services:
-
Client Service
-
Communication Service
-
Task Schedule
-
Mobile Notification Service
-
Workflow Engine
-
-
In an Enterprise Server system, ensure to stop the Advance Server Service.
-
In a client computer, ensure to stop the Client service.
-
In a client machine which is connected to an Enterprise Server, ensure to stop the Advance Server Service and Client Service.
-
Close all AVEVA Work Tasks related sites and applications.
-
To stop IIS, run Command Prompt as an Administrator, and type iisreset /stop.
-
Delete the WorkflowManagementTemp folder from C:\Windows\Temp.
-
Delete the AVEVA Work Tasks Cache files and folders from C:\Windows\Microsoft.NET\Framework64\v4.0.XXXXX\Temporary ASP.NET Files\.
-
Start the AVEVA Work Tasks related services.
-
To start IIS, run Command Prompt as an Administrator, and type iisreset /start.
-