Farm Configuration Error
- Last UpdatedJun 06, 2024
- 2 minute read
1. Issue:
When you run the Farm Configuration Wizard, the following error message appears.

Probable Cause
This error occurs if there is a change in the IP address of the machine, where AVEVA Work Tasks is configured.
Resolution
Restart all the AVEVA Work Tasks Services.
2. Continuous Error Logs in WTLogger Console
The following errors are logged continuously in the WTLogger Console.
Error: Cannot add duplicate collection entry of type 'virtualDirectory' with uni
que key attribute 'path' set to '/BPMUITemplates'
).Skelta.Core.DS.SingleTableObjectDataRowException: Could not load data for tab
le (SKRepository), No matching record found for column: @Name, value: Filename:
Error: Cannot add duplicate collection entry of type 'virtualDirectory' with uni
que key attribute 'path' set to '/BPMUITemplates'
, Repository:$CentralConfig$, severityLevel: Fatal
at Skelta.Core.DS.SingleTableObject.LoadRowData()
at Skelta.Core.DS.SingleTableObject.EnsureRecordsInTableRow()
at Skelta.Core.DS.SingleTableObjectWithName.Initialize(String name)
at Skelta.FarmManager.Repository..ctor(String name)
at Workflow.NET.Config.GetDataSourceType(String Application), Module - C:\Win
dows\Microsoft.Net\assembly\GAC_MSIL\Workflow.NET.NET2\v4.0_5.0.0.0__c932f724c98
4e915\Workflow.NET.NET2.dll ,Assembly version = 5.0.1001.0, ThreadID - 3, BPM201
7SP16, Process - SKClientSrv, 15:07:23.444
? - Error while getting the data source type for application ( Filename:
Error: Cannot add duplicate collection entry of type 'virtualDirectory' with uni
que key attribute 'path' set to '/BPMUITemplates'
).Skelta.Core.DS.SingleTableObjectDataRowException: Could not load data for tab
le (SKRepository), No matching record found for column: @Name, value: Filename:
Error: Cannot add duplicate collection entry of type 'virtualDirectory' with uni
que key attribute 'path' set to '/BPMUITemplates'
, Repository:$CentralConfig$, severityLevel: Fatal
at Skelta.Core.DS.SingleTableObject.LoadRowData()
at Skelta.Core.DS.SingleTableObject.EnsureRecordsInTableRow()
at Skelta.Core.DS.SingleTableObjectWithName.Initialize(String name)
at Skelta.FarmManager.Repository..ctor(String name)
at Workflow.NET.Config.GetDataSourceType(String Application), Module - C:\Windows\Microsoft.Net\assembly\GAC_MSIL\Workflow.NET.NET2\v4.0_5.0.0.0__c932f724c98
4e915\Workflow.NET.NET2.dll ,Assembly version = 5.0.1001.0, ThreadID - 3, BPM201
7SP16, Process - SKClientSrv, 15:07:24.242
? - Error while getting the data source type for application ( Filename:
Error: Cannot add duplicate collection entry of type 'virtualDirectory' with unique key attribute 'path' set to '/BPMUITemplates'
Probable Cause
While uninstalling AVEVA Work Tasks from a machine, all the files might not be completely removed, due to some issues. When you install AVEVA Work Tasks on this machine, the above issue might occur.
Resolution
To resolve this issue, perform the following:
-
Browse to the Installed folder of AVEVA Work Tasks.
-
Remove the folder.
-
Restart the machine.
-
Install the latest version of AVEVA Work Tasks.
3. The Farm Configuration Wizard crashes while configuring License Server 3.6 version
Probable Cause:
The port number goes as blank while configuring License server.
Resolution:
Provide the port number as 55555 to continue with Farm configuration.