Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

AVEVA™ Measurement Advisor

Enable end-of-day (EOD) flow projection debugging

  • Last UpdatedSep 19, 2024
  • 1 minute read
  1. Define the location where the debugging should be enabled.

    For more information, see Define the server or project location where configuration overrides apply.

  2. On the Select Table tab, double-click the Task List row.

    The taskList tab appears.

  3. Locate the entry for the bal_calcEODproj row on the taskList tab located with the CD_STATION_VOLUMES entries.

  4. Add "@EODdebug = Y" to the arguments as shown in the image below.


  5. Save and load these configuration changes.

    For more information, see Save and load configuration changes.

    Notes: If end-of-day (EOD) projection debugging is enabled, all calculated end-of-day projection records are written to the EODworksetDebug table in the EFM database. For more information, see About Using End-of-Day (EOD) Flow Projection Debugging in the AVEVA Measurement Advisor User Guide.

    The data in the EODworksetDebug table must be manually cleaned up when the data is no longer required and debugging has completed.