AVEVA™ Measurement Advisor

Example of system and meter configuration

  • Last UpdatedSep 19, 2024
  • 1 minute read

Consider the following system and the system and meter configuration:

  • Contract timezone: Mountain Standard (MST)

  • Official contract hour: 9:00 AM

  • Field device timezone: Pacific Standard (one hour earlier than Mountain Standard)

  • Field device contract hour: 8:00 AM

For an hourly split record, with a field timestamp of August 15th at 10:20 AM, the times will be as follows:

hostHourly

August 15th, 09:00

The hour in which the record resides.

hostDaily

August 15th, 09:00

The official contract hour for the gas day.

hostMonthly

August 1st, 09:00

The gas day at the top of the month.

fieldHourly

August 15th, 10:00

The hour in which the record resides in the Pacific timezone.

fieldDaily

August 15th, 08:00

The field device contract hour in the Pacific timezone.

fieldMonthly

August 1st, 08:00

the field device contract hour in the Pacific timezone for the beginning of the month.