AVEVA™ Measurement Advisor

Pulse and Corrector meter edit state

  • Last UpdatedDec 20, 2024
  • 2 minute read

When you make edits to your Pulse or Corrector meter data, the following occurs:

  • If Pressure is edited, the Volume, Energy, Mass, Fp*Ft*Fpv2 will be calculated. The Edit State will be set to Edited.

  • If Temperature is edited, the Volume, Energy, Mass, Fp*Ft*Fpv2 will be calculated. The Edit State will be set to Edited.

  • If Uncorrected Volume is edited and Pulse Count Calculation Policy = Calculate UV from PC, the Volume, Energy, and Mass will be calculated. The Edit State will be set to Edited.

  • If Uncorrected Volume is edited and Pulse Count Calculation Policy = Calculate PC from UV, the Pulse Count, Volume, Energy, and Mass will be calculated. The Edit State will be set to Edited.

  • If Uncorrected Volume is edited and Pulse Count Calculation Policy = None, the Volume, Energy, and Mass will be calculated. The Edit State will be set to Edited.

  • If Pulse Count is edited and the Pulse Count Calculation Policy = Calculate UV from PC, the Uncorrected Volume, Volume, Energy, and Mass will be calculated. The Edit State will be set to Edited.

  • If Pulse Count is edited and Pulse Count Calculation Policy = Calculate PC from UV, nothing will be calculated. The Edit State will be set to Edited.

  • If Pulse Count is edited and Pulse Count Calculation Policy = None, nothing will be calculated. The Edit State will be set to Edited.

  • If Volume is edited, the Energy and Mass will be calculated. The Edit State will be set to Manual Override.

  • If Mass is edited, nothing will be calculated. The Edit State will be set to Manual Override.

  • If Energy is edited, the Edit State will be set to Manual Override.