List of SCADA commands for Gas Quality
- Last UpdatedAug 22, 2025
- 2 minute read
List of SCADA commands associated with Gas Quality (GQ)
|
SCADA Command |
Description |
|---|---|
|
Automatic Time Synchronization |
Synchronizes Electronic Flow Measurement (EFM) device with the host ( AVEVA Measurement Advisor) clock, as long as the synchronization does not cause the EFM device's clock to cross an hour boundary. |
|
Download Default GQ |
Download the default GQ configuration to a chromatograph's configuration area within a general-purpose flow computer. This information comes from the GQ when the Analysis Source is configured as a Chromatograph. The values entered on the Chromatograph tab in AVEVA Measurement Advisor are sent to the Flow Computer. |
|
Download GQ |
Manual request to download the GQ configuration to the connected meter's configuration area. |
|
Forced Time Synchronization |
Forces a synchronize between the EFM device and the host's clock (not taking into account on whether an hour boundary would be crossed). |
|
Upload GQ Configuration |
Upload all relevant configuration information for all of the gas analysis sources on the EFM devices so that they can be compared to AVEVA Measurement Advisor's configuration. |
|
Upload GQ Alarms |
Uploads all outstanding GQ alarm logs recorded on this EFM device to AVEVA Measurement Advisor. |
|
Upload GQ Current Conditions |
Uploads current conditions for all gas analysis sources on the EFM device to AVEVA Measurement Advisor. |
|
Upload GQ Daily History |
Uploads all outstanding daily GQ history for all metering runs and gas analysis sources on the EFM device to AVEVA Measurement Advisor. |
|
Upload GQ Hourly History |
Uploads all outstanding hourly GQ history for all metering runs and gas analysis sources on the EFM device to AVEVA Measurement Advisor. |
|
Upload GQ Events |
Upload all outstanding GQ event logs recorded on the EFM device to AVEVA Measurement Advisor. |