AVEVA™ Measurement Advisor

Coriolis meter operational validation

  • Last UpdatedSep 24, 2024
  • 1 minute read

The Operational Validation for Coriolis Meter is configured in the Validation Summary.

Embedded Image (65% Scaling) (LIVE)

There are three operational validation methods in use with Coriolis Meters:

  • MTR pulse cnt oper chk: If enabled, Pulse Count operational check validation will be done when Coriolis Calculation Policy is set to Calc from Pulse Count.

  • MTR uncompensated mass oper chk: If enabled, Uncompensated Mass operational check validation will be done when Coriolis Calculation Policy is set to Calc from Uncompensated Mass

  • MTR mass oper chk: This is available in Meter Operational Validation group. If enabled, Mass operational check will be done when Coriolis Calculation Policy is set to Calc from Compensated Mass