Prepare for and send zone quality (ZQ) data to Autosol Communications Manager (ACM)

Prepare for and send zone quality (ZQ) data to Autosol Communications Manager (ACM)

  • Last UpdatedSep 15, 2025
  • 1 minute read

The stored procedure [moveXferQueueToGQDownload] queues ZQ data for download from AVEVA Measurement Advisor to Autosol Communications Manager (ACM). This stored procedure uses the following rules:

  • For each ZQ in the batch, the routine looks up associated measurement connectivity to find all stations that have multiple meters using the ZQ. If it finds any, the ZQ data is queued for download to the station(s).

  • If the ZQ is associated with only one meter in a station or is not connected to a station, the ZQ data is queued for download to that meter.

  • A tolerance check compares the data to its last completed ZQ data download to see whether it needs to be queued or not. If the new data exceeds tolerances as configured in AVEVA Measurement Advisor, it is queued for download. For more information on the tolerances used, see the GQ Deadband values on the Properties for Gas Quality (GQ) : Zone Analysis Tab.

  • Any in-progress ZQ to be replaced by new ZQ is marked as "Failed" in the Scada GQ Downloads screen. For more information, see Scada GQ Downloads.

To configure ZQ data for download to ACM

Note: For more information on configuration, see the subtopics of the chapter "Use the MeasConfig Tool to Make Updates to the Object Registry" beginning at Select a Table.

  1. In the configDesc table, set CD_MULTIPLE_SCADA_ENV to Y.

  2. In the configDesc table, set CD_USE_SCADA_DATA_CONNECTOR to Y.

  3. Override the taskList entry for the table moveXferQueueToGQDownload to set each needed scadaEnv argument.