AVEVA™ Measurement Advisor

Pulse host-calculated meter

  • Last UpdatedSep 26, 2025
  • 3 minute read

Embedded Image (65% Scaling) (LIVE)

Selected Fields on Meter Properties: Pulse Host Calculated Tab

Pulse Host Calculated?

Description

Generate history

Enables the collection of hourly Historical data for this host meter.

Calculate corrected volume

Enable the calculation of the corrected volume (if not measured).

Compute energy

Enable the calculation of the energy using the current active gas analysis data (if not measured).

Compute mass

Enable the calculation of the mass using the current corrected volume (if not measured).

Compute hydrocarbon dewpoint

Enable the calculation of the hydrocarbon dewpoint and phase envelope (if the Hydrocarbon Dewpoint module is installed).

Pulse Input Paths

The Pulse Input Paths (for example, the Static pressure input path) are more flexible, allowing you to define where the input data can be read from, and should be used whenever you are defining new inputs. The Input Path should be formatted as follows: tableName.pointName.fieldName

Static temperature input path

Defines a path to a table, point and field in the RTDB that measures the static temperature for this meter

Static pressure input path

Defines a path to a table, point and field in the RTDB that measures the static pressure for this meter.

Uncorrected volume input path

Defines a path to a table, point and field in the RTDB that measures the uncorrected volume for this meter.

Corrected volume input path

Defines a path to a table, point and field in the RTDB that measures the corrected volume for this meter.

Energy input path

Defines a path to a table, point and field in the RTDB that measures the energy for this meter.

Mass input path

Defines a path to a table, point and field in the RTDB that measures the mass for this meter.

Pulse Analog/Rate Inputs

The Pulse Analog / Rate Inputs (for example, the Static pressure input) restrict the input to either a rate or an analog, depending on the type of input. This is is provided for backwards compatibility. The Pulse Input Paths should be used when defining new inputs.

Static pressure input

Defines the analog point name in the RTDB that measures the static pressure for this meter.

Static temperature input

Defines the analog point name in the RealTime database (RTDB) that measures the static temperature for this meter.

Uncorrected volume input

Defines the rate point name in the RTDB that measures the uncorrected volume for this meter (if not calculating).

Corrected volume input

Defines the rate point name in the RTDB that measures the corrected volume for this meter (if not calculating).

Energy input

Defines the rate point name in the RTDB that measures the energy for this meter (if not calculating).

Mass input

Defines the rate point name in the RTDB that measures the mass for this meter (if not calculating).

Note: If an invalid name or path is entered, it will not be replicated to the RealTime database. An error will be written to the meas2realtime log indicating the meter with the incorrect path.